Next: Arithmetic, Previous: Constants, Up: RTL
Here are the RTL expression types for describing access to machine registers and to main memory.
(reg:
m n)
FIRST_PSEUDO_REGISTER
), this stands for a reference to machine
register number n: a hard register. For larger values of
n, it stands for a temporary value or pseudo register.
The compiler's strategy is to generate code assuming an unlimited
number of such pseudo registers, and later convert them into hard
registers or into memory references.
m is the machine mode of the reference. It is necessary because machines can generally refer to each register in more than one mode. For example, a register may contain a full word but there may be instructions to refer to it as a half word or as a single byte, as well as instructions to refer to it as a floating point number of various precisions.
Even for a register that the machine can access in only one mode, the mode must always be specified.
The symbol FIRST_PSEUDO_REGISTER
is defined by the machine
description, since the number of hard registers on the machine is an
invariant characteristic of the machine. Note, however, that not
all of the machine registers must be general registers. All the
machine registers that can be used for storage of data are given
hard register numbers, even those that can be used only in certain
instructions or can hold only certain types of data.
A hard register may be accessed in various modes throughout one
function, but each pseudo register is given a natural mode
and is accessed only in that mode. When it is necessary to describe
an access to a pseudo register using a nonnatural mode, a subreg
expression is used.
A reg
expression with a machine mode that specifies more than
one word of data may actually stand for several consecutive registers.
If in addition the register number specifies a hardware register, then
it actually represents several consecutive hardware registers starting
with the specified one.
Each pseudo register number used in a function's RTL code is
represented by a unique reg
expression.
Some pseudo register numbers, those within the range of
FIRST_VIRTUAL_REGISTER
to LAST_VIRTUAL_REGISTER
only
appear during the RTL generation phase and are eliminated before the
optimization phases. These represent locations in the stack frame that
cannot be determined until RTL generation for the function has been
completed. The following virtual register numbers are defined:
VIRTUAL_INCOMING_ARGS_REGNUM
When RTL generation is complete, this virtual register is replaced
by the sum of the register given by ARG_POINTER_REGNUM
and the
value of FIRST_PARM_OFFSET
.
VIRTUAL_STACK_VARS_REGNUM
FRAME_GROWS_DOWNWARD
is defined to a nonzero value, this points
to immediately above the first variable on the stack. Otherwise, it points
to the first variable on the stack.
VIRTUAL_STACK_VARS_REGNUM
is replaced with the sum of the
register given by FRAME_POINTER_REGNUM
and the value
STARTING_FRAME_OFFSET
.
VIRTUAL_STACK_DYNAMIC_REGNUM
This virtual register is replaced by the sum of the register given by
STACK_POINTER_REGNUM
and the value STACK_DYNAMIC_OFFSET
.
VIRTUAL_OUTGOING_ARGS_REGNUM
STACK_POINTER_REGNUM
).
This virtual register is replaced by the sum of the register given by
STACK_POINTER_REGNUM
and the value STACK_POINTER_OFFSET
.
(subreg:
m reg bytenum)
subreg
expressions are used to refer to a register in a machine
mode other than its natural one, or to refer to one register of
a multi-part reg
that actually refers to several registers.
Each pseudo-register has a natural mode. If it is necessary to
operate on it in a different mode—for example, to perform a fullword
move instruction on a pseudo-register that contains a single
byte—the pseudo-register must be enclosed in a subreg
. In
such a case, bytenum is zero.
Usually m is at least as narrow as the mode of reg, in which case it is restricting consideration to only the bits of reg that are in m.
Sometimes m is wider than the mode of reg. These
subreg
expressions are often called paradoxical. They are
used in cases where we want to refer to an object in a wider mode but do
not care what value the additional bits have. The reload pass ensures
that paradoxical references are only made to hard registers.
The other use of subreg
is to extract the individual registers of
a multi-register value. Machine modes such as DImode
and
TImode
can indicate values longer than a word, values which
usually require two or more consecutive registers. To access one of the
registers, use a subreg
with mode SImode
and a
bytenum offset that says which register.
Storing in a non-paradoxical subreg
has undefined results for
bits belonging to the same word as the subreg
. This laxity makes
it easier to generate efficient code for such instructions. To
represent an instruction that preserves all the bits outside of those in
the subreg
, use strict_low_part
around the subreg
.
The compilation parameter WORDS_BIG_ENDIAN
, if set to 1, says
that byte number zero is part of the most significant word; otherwise,
it is part of the least significant word.
The compilation parameter BYTES_BIG_ENDIAN
, if set to 1, says
that byte number zero is the most significant byte within a word;
otherwise, it is the least significant byte within a word.
On a few targets, FLOAT_WORDS_BIG_ENDIAN
disagrees with
WORDS_BIG_ENDIAN
.
However, most parts of the compiler treat floating point values as if
they had the same endianness as integer values. This works because
they handle them solely as a collection of integer values, with no
particular numerical value. Only real.c and the runtime libraries
care about FLOAT_WORDS_BIG_ENDIAN
.
Between the combiner pass and the reload pass, it is possible to have a
paradoxical subreg
which contains a mem
instead of a
reg
as its first operand. After the reload pass, it is also
possible to have a non-paradoxical subreg
which contains a
mem
; this usually occurs when the mem
is a stack slot
which replaced a pseudo register.
Note that it is not valid to access a DFmode
value in SFmode
using a subreg
. On some machines the most significant part of a
DFmode
value does not have the same format as a single-precision
floating value.
It is also not valid to access a single word of a multi-word value in a
hard register when less registers can hold the value than would be
expected from its size. For example, some 32-bit machines have
floating-point registers that can hold an entire DFmode
value.
If register 10 were such a register (subreg:SI (reg:DF 10) 4)
would be invalid because there is no way to convert that reference to
a single machine register. The reload pass prevents subreg
expressions such as these from being formed.
The first operand of a subreg
expression is customarily accessed
with the SUBREG_REG
macro and the second operand is customarily
accessed with the SUBREG_BYTE
macro.
(scratch:
m)
reg
by either the local register allocator or
the reload pass.
scratch
is usually present inside a clobber
operation
(see Side Effects).
(cc0)
With this technique, (cc0)
may be validly used in only two
contexts: as the destination of an assignment (in test and compare
instructions) and in comparison operators comparing against zero
(const_int
with value zero; that is to say, const0_rtx
).
With this technique, (cc0)
may be validly used in only two
contexts: as the destination of an assignment (in test and compare
instructions) where the source is a comparison operator, and as the
first operand of if_then_else
(in a conditional branch).
There is only one expression object of code cc0
; it is the
value of the variable cc0_rtx
. Any attempt to create an
expression of code cc0
will return cc0_rtx
.
Instructions can set the condition code implicitly. On many machines,
nearly all instructions set the condition code based on the value that
they compute or store. It is not necessary to record these actions
explicitly in the RTL because the machine description includes a
prescription for recognizing the instructions that do so (by means of
the macro NOTICE_UPDATE_CC
). See Condition Code. Only
instructions whose sole purpose is to set the condition code, and
instructions that use the condition code, need mention (cc0)
.
On some machines, the condition code register is given a register number
and a reg
is used instead of (cc0)
. This is usually the
preferable approach if only a small subset of instructions modify the
condition code. Other machines store condition codes in general
registers; in such cases a pseudo register should be used.
Some machines, such as the SPARC and RS/6000, have two sets of
arithmetic instructions, one that sets and one that does not set the
condition code. This is best handled by normally generating the
instruction that does not set the condition code, and making a pattern
that both performs the arithmetic and sets the condition code register
(which would not be (cc0)
in this case). For examples, search
for `addcc' and `andcc' in sparc.md.
(pc)
(pc)
may be validly used only in
certain specific contexts in jump instructions.
There is only one expression object of code pc
; it is the value
of the variable pc_rtx
. Any attempt to create an expression of
code pc
will return pc_rtx
.
All instructions that do not jump alter the program counter implicitly by incrementing it, but there is no need to mention this in the RTL.
(mem:
m addr alias)
The construct (mem:BLK (scratch))
is considered to alias all
other memories. Thus it may be used as a memory barrier in epilogue
stack deallocation patterns.
(addressof:
m reg)
Pmode
. If there are any addressof
expressions left in the function after CSE, reg is forced into the
stack and the addressof
expression is replaced with a plus
expression for the address of its stack slot.